AA13 initCode failed or OOG
The EntryPoint failed to create the smart account with the initCode
provided. There are two possible reasons:
- The
initCode
ran out of gas - The
initCode
reverted during the account deployment process
Possible solutions
- Verify that the factory address in the
initCode
is correct (the factory address is the first 20 bytes of theinitCode
). - Verify that the
initCode
is correct. - Check whether the
verificationGasLimit
is sufficient for theinitCode
to complete without running out of gas. - If the root cause is a revert, investigate why the
initCode
reverts during the account deployment process using tools like Tenderly.